Description
This alarm occurs if abnormal internal data is detected during the access to the job data of operating/editing software.
Subcode description
An attempt was made to change
the contents for the job
prohibited from being edited.
Causes and remedies
| Cause | Remedy |
|---|---|
| Software (incorrect setting) | 1. Reset the alarm. 2. Check the following settings. • Edit prohibition setting in the job header: If editing is prohibited, release the edit prohibition. |
| Software (malfunction) | 1. Reset the alarm. 2. To edit this job, release edit protection. 3. If this happens again, delete the job where the alarm occurred. 4. If the alarm recurs despite the above measures, initialize the job in maintenance mode and reload the saved job. |
| Other | If the alarm occurs again after implementing the countermeasures, contact our service department and describe the circumstances when CMOS.BIN was saved (operating procedure, etc.). |