[Cause]
PowerWaveErrorCode No.362 occurred. The output voltage is outside the production monitoring “Weld Curve” limits. The output voltage may be below the lower voltage limit or above the upper voltage limit.
[Countermeasure]
Check the welding setpoints, changes in settings, workpiece position, and other factors. Settings include, but are not limited to, gas flow rate, wire type and diameter, stickout, welding cable length, spatter accumulation, and electrode tip wear. Check that the voltage limits for the weld curve are within an appropriate range for the application. This also includes “Seconds Until Voltage Limit” (time until the voltage limit, in seconds) in the “General Settings” section. To exclude the start and end of welding, check that the start delay and end delay are set appropriately.