8101
Category: Alarm
Cause
Condition: motor and drive overloaded. Causes:
- Continuous operation above the drive rated load.
- Control system parameters set inappropriately.
- Motor or position detector wiring incorrect.
- Motor position detector defective.
Corrective action
- Set the drive status display (P0.002) to 12 and monitor whether the average load ratio [%] continuously exceeds 100% or more. If it continuously exceeds 100% or more (see the load ratio versus operating time curve in Appendix A), increase motor capacity or reduce the load.
- Check whether the mechanical system oscillates or acceleration/deceleration is set too fast.
- Check whether U, V, W and motor encoder wiring are correct.
- Return the unit to the dealer or original manufacturer for inspection and repair. Reset the alarm.