Description
The self-diagnostic function for the general-purpose safety input signal detected an error.
Subcode description
The meaning of each sub code is
as follows:
CPU1 1:GSIN1
CPU1 2:GSIN2
CPU2 1:GSIN1
CPU2 2:GSIN2
Causes and remedies
| Cause | Remedy |
|---|---|
| Cable (abnormal) | 1. Reset the alarm. 2. If the alarm recurs, check the connectors and other connections of the external device. |
| ASF01 board (abnormal) | 1. Reset the alarm. 2. If the alarm recurs, replace the ASF01 board. For a system with multiple ASF01 boards connected, replace the ASF01 board connected to the signal that generated the alarm. |
| Other | If the alarm occurs again after implementing the countermeasures, contact our service department and describe the circumstances when CMOS.BIN was saved (operating procedure, etc.). |