Description
Setup process of MOTION section was not properly completed when the power turned ON.
Subcode description
The position data of when the
power supply was turned OFF
cannot be transmitted to the
servo control section
Causes and remedies
| Cause | Remedy |
|---|---|
| SDCA01 board (abnormal) | 1. Turn the power off and back on. 2. If the alarm recurs, replace the SDCA01 board. As a precaution, save CMOS.BIN before replacing the board. |
| Software (malfunction) | 1. Turn the power off and back on. 2. If the alarm recurs, save CMOS.BIN and report the circumstances (operating procedure, etc.) to our service department. |