Description
The converter detected circuit-breaker overcurrent.
Subcode description
Indicates the control-axis number on which the error was detected.
Causes and remedies
| Cause | Remedy |
|---|---|
| Rectifier (abnormal) | 1. Turn the power off and back on. 2. If the alarm recurs, replace the converter. |
| SDCA01 board (abnormal) | 1. Turn the power off and back on. 2. If the alarm recurs, replace the SDCA01 board. As a precaution, save CMOS.BIN before replacing the board. |
| Other | If the alarm occurs again after implementing the countermeasures, contact our service department and describe the circumstances when CMOS.BIN was saved (operating procedure, etc.). |