Description
An error has occurred in MotoFit function.
Subcode description
Board / cable error
Causes and remedies
| Cause | Remedy |
|---|---|
| ACP02 board (abnormal) | 1. Check the force-sensor cable connections to the sensor and sensor board, then reset the alarm. 2. If the alarm recurs, turn the power off, then check the board wiring inside the controller and the sensor board connections. 3. If the alarm recurs with normal cable and board connections, save CMOS.BIN and report the circumstances to our service department. |