Description
Subcode description
The data received from the
vision system is incorrect.
Causes and remedies
| Cause | Remedy |
|---|---|
| Software (incorrect setting) | 1. Reset the alarm. 2. Check the following settings. • Vision system communication settings • Vision system detection settings |
| Cable (abnormal) | 1. Reset the alarm. 2. If the alarm recurs, check the connections of the following cables. • Cable between the vision system and YRC1000 |
| Other | If the alarm occurs again after implementing the countermeasures, contact our service department and describe the circumstances when CMOS.BIN was saved (operating procedure, etc.). |