Description
Cooling fan setting parameter disabled.
Subcode description
Causes and remedies
| Cause | Remedy |
|---|---|
| Software (incorrect setting) | 1. Reset the alarm. 2. Check the cooling-fan parameter settings SVS and S2C. Refer to the parameter table in the cabinet and set the correct value. |