Error handling: Controller power OFF;
Error reset: Possible
Description: The AC external power supply dropped to or below the rated value -20% for 1 to 2 seconds.

External power supply
AC200V
Control power supply AVR
NFB
Remote
AC error signal
AVR
Output cutoff
Main CPU board
CPLD
Power sequence board
Main causes:
-
A problem with the external AC power supply.
-
A problem with wiring or connector connections inside the controller.
-
The AVR is faulty.
-
A problem with the power sequence board.
Countermeasures:
-
Check the external power supply voltage.
-
Check the internal controller wiring and connector connections for problems.
-
Replace the AVR.
-
Replace the power sequence board.