Description
The YRC1000 stores some of the data required for system operation on the SD card in the ACP01 board. When the data changes, the new data is written to the SD card. This alarm occurs if the write process cannot be performed normally. Since this alarm also occurs when the SD card cannot be accessed, it is not recorded in the alarm history.
Subcode description
PANELBOX.LOG file broken
Causes and remedies
| Cause | Remedy |
|---|---|
| Data (abnormal) | 1. Turn the power off and back on. 2. If the alarm recurs, open Maintenance Mode - System - Data Reconstruction, and execute data reconstruction. |
| SD card board (abnormal) | 1. Turn the power off and back on. 2. If the alarm recurs, replace the SD card. Save CMOS.BIN before replacing the SD card. After replacing the SD card, load CMOS.BIN saved before the alarm occurred. |