Error handling: Motor power OFF.
Error reset: Possible.
Content: The settings specifying the number of safety circuits do not match between the DIP switch (SW2-1) on the power sequence board and the jumper (JP2 or JP3) on the power supply unit control board (1VH).
Main causes:
-
The switch settings on the power sequence board or power supply unit control board are incorrect.
-
A problem with the power sequence board.
-
A problem with the power supply unit control board.
Countermeasures:
-
Check that the DIP switch (SW2-1) setting on the power sequence board matches the jumper (JP2 or JP3) setting on the power supply unit control board. With correct settings:
-
Replace the power sequence board.
-
Replace the power supply unit control board.