8497
Category: Alarm
Cause
- Abnormal vibration detected in motor speed
- Inertia ratio (Pn103) is higher than the actual value or has changed significantly
Corrective action
- Check abnormal motor noise and operating speed and torque waveforms; reduce motor speed or reduce speed-loop gain (Pn100).
- Check the inertia ratio and set inertia ratio (Pn103) correctly.