Description
An error occurred in the ASCII-IF control processing.
Subcode description
Job name in the PLAYBACK file is
wrong at the time of
IBGNSTART PLAYBACK=ON
instruction executed.
Causes and remedies
| Cause | Remedy |
|---|---|
| Software (incorrect setting) | Change the job name in the playback file so that it matches the name of the job executing the IBGNSTART PLAYBACK=ON instruction. |
| Other | If the alarm occurs again after implementing the countermeasures, contact our service department and describe the circumstances when CMOS.BIN was saved (operating procedure, etc.). |