Error handling: Controller power OFF;
Error reset: Possible
Description: This error occurs when the AC external power supply voltage drops to or below the rated value -30% for 1/50 to 1/30 second.

External power supply
AC200V
Control power supply AVR
NFB
Remote
AC error signal
AVR
Output cutoff
Main CPU board
CPLD
Power sequence board
Main causes:
-
The AC external power supply is faulty.
-
A problem with wiring or connector connections inside the controller.
-
A problem with the AVR.
-
A problem with the power sequence board.
Countermeasures:
-
Check the external power supply voltage.
-
Check the internal controller wiring and connector connections for problems.
-
Replace the AVR.
-
Replace the power sequence board.

[NOTE]
It is normal for this error to occur when the controller power switch is turned off.