[Cause]
The applied force specified by the applied-force condition or the applied-force instruction is lower than the minimum applied force based on force adjustment.
[Countermeasure]
Increase the specified applied force, or perform force adjustment again.
代码
Note 1: When the specified applied force=0, the system attempts to press between the electrode tips at the minimum allowable force (equivalent to the straight-line slice of line-opening interpolation). At the force adjustment point, SVGN-016 does not occur even if the straight-line slice of linear interpolation is not 0.
Note 2: To reliably produce a low applied force, use force adjustment to add an adjustment point at that force or a lower force.
Note 3: To apply pressure correctly at low force, reduce the contact speed as much as possible.
Note 4: From R-30iB Plus onward, pressure equivalent to 1000N is applied as standard when measuring wear. If this alarm occurs during wear measurement, adjust the applied force even at 1000N.