Description
An error was detected at memory check.
Subcode description
The memory for the operating-time database is damaged.
Causes and remedies
| Cause | Remedy |
|---|---|
| Software (data error) | 1. Reset the alarm. 2. If the alarm recurs, initialize the operating-time database in maintenance mode, then load the backed-up operating-time database. |
| ACP01 board (abnormal) | 1. Reset the alarm. 2. If the alarm recurs, replace the ACP01 board. As a precaution, save CMOS.BIN before replacing the board. After replacing the ACP01 board, remove the SD card from the original ACP01 board and insert it into the new ACP01 board. |
| AIF01 board (abnormal) | 1. Reset the alarm. 2. If the alarm recurs, replace the AIF01 board. As a precaution, save CMOS.BIN before replacing the board. After replacing the AIF01 board, load CMOS.BIN saved before the alarm occurred. |
| Other | If the alarm occurs again after implementing the countermeasures, contact our service department and describe the circumstances when CMOS.BIN was saved (operating procedure, etc.). |