Error handling: Motor power OFF.
Error reset: Possible.
Description: A drop in the 6.9V power supply voltage was detected inside the power supply unit power board (1WU).
Main causes:
-
A problem with the power supply unit power board.
-
An open circuit in the signal line between the power supply unit power board and power supply unit control board.
-
A problem with the power supply unit control board.
-
A problem with the power block.
-
A problem with the power regeneration unit. (E03)
Countermeasures:
-
Check the internal wiring between the power supply unit power board (X362) and power supply unit control board (X306) for open circuits, etc.
-
Replace the power supply unit.
-
Replace the power supply unit control board.
-
Replace the power block.
-
Replace the power regeneration unit. (E03)