Description
The system software monitors if the setup of MOTION section software is properly completed when the power turned ON. This alarm occurs if the MOTION section software fails to properly complete the setup. Note that the alarm AL-1051 (SET-UP PROCESS ERROR) occurs in conjunction with this alarm. (For details, refer to AL-1051.) The error and message of interior temperature error and interior fan error might be complicated because it doesn't starting up normally in this state.
Subcode description
Motion instruction setup
incomplete.
Causes and remedies
| Cause | Remedy |
|---|---|
| ACP01 board (abnormal) | 1. Turn the power off and back on. 2. If the alarm recurs, replace the ACP01 board. As a precaution, save CMOS.BIN before replacing the board. After replacing the ACP01 board, remove the SD card from the original ACP01 board and insert it into the new ACP01 board. |
| Software (malfunction) | 1. Turn the power off and back on. 2. If the alarm recurs, save CMOS.BIN and report the circumstances (operating procedure, etc.) to our service department. |
| Other | If the alarm occurs again after implementing the countermeasures, contact our service department and describe the circumstances when CMOS.BIN was saved (operating procedure, etc.). |