Description
An error was detected by the diagnostic function for the feedback signal from the general-purpose safety output.
Subcode description
Subcodes are defined as follows.
CPU1 1: GSEDM1
CPU1 2: GSEDM2
CPU2 1: GSEDM1
CPU2 2: GSEDM2
Causes and remedies
| Cause | Remedy |
|---|---|
| IM-YE250/5-80P terminal block board (abnormal) | 1. Reset the alarm. 2. If the alarm recurs, replace the IM-YE250/5-80P terminal-block board. For a system with multiple IM-YE250/5-80P terminal block boards connected, replace the IM-YE250/5-80P terminal block board connected to the control group that generated the alarm. |
| ASF01 board (abnormal) | 1. Reset the alarm. 2. If the alarm recurs, replace the ASF01 board. For a system with multiple ASF01 boards connected, replace the ASF01 board connected to the signal that generated the alarm. |
| Other | If the alarm occurs again after implementing the countermeasures, contact our service department and describe the circumstances when CMOS.BIN was saved (operating procedure, etc.). |