Error handling: Motor power OFF.
Error reset: Possible.
Description: The DC supply voltage on the servo board has dropped.
Main causes:
-
Incorrect voltage adjustment of the control power AVR.
-
A problem with the control power AVR.
-
A problem with the servo board.
-
A problem with the power sequence board.
-
The harness between the servo board (X501) and the motherboard (X207) has an open circuit or poor connection.
-
A problem with the motherboard.
Countermeasures:
-
Check the 5V voltage between the test pins on the power sequence board and adjust it to within 5.05 to 5.15V.
-
Replace the control power AVR.
-
Replace the servo board.
-
Replace the power sequence board.
-
Check the harness between the servo board (X501) and motherboard (X207) for open circuits or poor connections.
-
Replace the motherboard.