[Cause]
PowerWaveErrorCode No.35 occurred. The voltage in one of the two input capacitors (bank B) exceeded the high-voltage limit. This alarm usually occurs with high input voltage. Failure of the switching board, output diode, main capacitor, contactor, or V-to-F feedback signal may also cause it.
[Countermeasure]
Check the input power (voltage and frequency). Check that the primary-side reconnection is set correctly for the input voltage. If the problem persists, before performing any other operations (power-off or jogging) after this alarm occurs, use the abnormal-state recording function ("Abnormal State Record" in the auxiliary menu) to obtain an image backup and contact the service center. If that function cannot be used, record the conditions and operating steps up to the alarm, obtain an image backup, and contact the service center.