Description
drive module arg and drive unit arg. The bleeder resistor is short-circuited or the current flowing through the bleeder device is too large.
Consequences
The system cannot operate until the fault is corrected, and the system will enter the "system interruption" (SYS HALT) state.
Possible causes
Damaged drain device or cable.
Recommended actions
Verify that the drain device is properly connected, verify that the drain device is not damaged, and verify that the drain device resistance is correct.