Description
Setup process of MOTION section was not properly completed when the power turned ON.
Subcode description
Unable to turn ON the PG power
supply for the mounted (PICK)
axis
Causes and remedies
| Cause | Remedy |
|---|---|
| SDCA01 board (abnormal) | 1. Turn the power off and back on. 2. If the alarm recurs, replace the SDCA01 board. As a precaution, save CMOS.BIN before replacing the board. |
| Software (malfunction) | 1. Turn the power off and back on. 2. If the alarm recurs, save CMOS.BIN and report the circumstances (operating procedure, etc.) to our service department. |