Description
The parameter setting do not match to system configuration setting.
Subcode description
The calculated CRC data match the CRC data stored in Flash Rom, but do not match the CRC data stored in the parameters.
Causes and remedies
| Cause | Remedy |
|---|---|
| Software (incorrect setting) | 1. Turn the power off and back on. 2. If the alarm recurs, follow the procedure below to recover. • Start maintenance mode and set security to safety mode. • Execute File - Initialize - Safety Board FLASH Data Reconfiguration. |
| ASF01 board (abnormal) | 1. Turn the power off and back on. 2. If the alarm recurs, replace the ASF01 board. |
| Other | If the alarm occurs again after implementing the countermeasures, contact our service department and describe the circumstances when CMOS.BIN was saved (operating procedure, etc.). |