Description
DryRun was rejected due to unfinished movement.
Consequences
Start will be rejected until unfinished movement has been
cleared.
Possible causes
DryRun execution cannot handle unfinished movement.
Recommended actions
Abort unfinished movement:
- Set PP to Cursor, i.e. to the position where PP currently is.
- Set PP to Main.