[Cause]
The system failed to write parameters to the timer board. The first digit indicates the welding machine number. The 2th digit represents the series number shown below. S0: Common, S1-S255: Parameter setting table 1-255, S256: Special function, S257-S260: Welding gun 1
-4。
The 3 number represents the error code.
[Countermeasure]
When the error code is 2, the parameter value is out of range. For parameter value ranges, please consult the welding machine manufacturer. Set the system variable of the corresponding parameter to correct value. WC1 S0:$IWCDGCON[1].$PARM[parameter number] WC1 S1-S255:$IWCDGS[parameter setting table number].$PARM[parameter number] WC1 S256:$IWCDGCON[2].$PARM[parameter number] WC1 S257-S260:$IWCDGCON[3-6].$PARM[parameter number] WC2 S0:$IWCDGCON[7].$PARM[parameter number] WC2 S1-S255:$IWCDGS2[parameter setting table number].$PARM[parameter number] WC2 S256:$IWCDGCON[8].$PARM[parameter number] WC2 S257-S260:$IWCDGCON[9-12].$PARM[parameter number] If the error code is not 2, please contact the Service Center.