Description
This alarm occurs if abnormal internal data is detected during the access to the job data of operating/editing software.
Subcode description
Unused handles were lacking
when an attempt was made to
open a job.
Causes and remedies
| Cause | Remedy |
|---|---|
| Software (incorrect setting) | Check the job call stack depth. • Create a job that uses as few stack entries as possible. |
| Software (malfunction) | 1. Reset the alarm. 2. If this happens again, delete the job where the alarm occurred. 3. If the alarm recurs despite the above measures, initialize the job in maintenance mode and reload the saved job. |
| Other | If the alarm occurs again after implementing the countermeasures, contact our service department and describe the circumstances when CMOS.BIN was saved (operating procedure, etc.). |