Error handling: Motor power OFF.
Error reset: Possible.
Description: The database (link table) used to control taught data in user memory has been corrupted (for example, after the editor accesses taught data).
Main causes:
-
The file system on the CF card is corrupted.
-
The main CPU board is faulty.
-
A problem with the power sequence board.
-
The AVR is faulty.
Countermeasures:
- When this error occurs, promptly set switch No. 8 of the DIP switch (dual in-line package switch) on the main CPU board to ON, then perform initialization and reload the taught data.

[NOTE]
The system memory cannot be completely initialized using the SYSINT command or auxiliary function 0805 System Initialization, because some system data is retained.
-
If this error still occurs, replace the CF card.
-
If this error still occurs, replace the main CPU board.
-
If this error still occurs, replace the power sequence board.
-
If this error still occurs, replace the AVR.