Description
An data error occurred during the access to position data of MOTION section.
Subcode description
An error occurred in exclusive
control during the position data
control process.
Causes and remedies
| Cause | Remedy |
|---|---|
| Software (malfunction) | Reset the alarm and execute the job again. |
| AIF01 board (abnormal) | 1. Reset the alarm and execute the job again. 2. If the alarm recurs, replace the AIF01 board. As a precaution, save CMOS.BIN before replacing the board. After replacing the AIF01 board, load CMOS.BIN saved before the alarm occurred. |
| ACP01 board (abnormal) | 1. Reset the alarm and execute the job again. 2. If the alarm recurs, replace the ACP01 board. As a precaution, save CMOS.BIN before replacing the board. After replacing the ACP01 board, remove the SD card from the original ACP01 board and insert it into the new ACP01 board. |