Description
When the control power was turned ON, an ASF board setting error was detected.
Subcode description
ACP01 board was not able to
recognize AIF01 board when the
control power turned ON.
Causes and remedies
| Cause | Remedy |
|---|---|
| Connector (abnormal) | 1. Turn the power off and back on. 2. If the alarm recurs, check that the following cables and connectors are connected and fully inserted. • ACP01 board • AIF01 board |
| AIF01 board (abnormal) | 1. Turn the power off and back on. 2. If the alarm recurs, replace the AIF01 board. Save CMOS.BIN before replacing the board. After replacing the AIF01 board, load CMOS.BIN saved before the alarm occurred. |
| ACP01 board (abnormal) | 1. Turn the power off and back on. 2. If the alarm recurs, replace the ACP01 board. Save CMOS.BIN before replacing the board. After replacing the ACP01 board, remove the SD card from the original ACP01 board and insert it into the new ACP01 board. |
| Other | If the alarm occurs again after implementing the countermeasures, contact our service department and describe the circumstances when CMOS.BIN was saved (operating procedure, etc.). |