8298
Category: Alarm
Cause
- Momentary power loss during parameter storage
- Momentary power loss while writing bus-type motor parameters
- Software has been updated
- Servo drive fault
Corrective action
- Confirm whether momentary power failure occurs during parameter value storage. Set an incorrect drive model (2001-0Bh), power on again, then set the correct drive model and power on again.
- Confirm whether momentary power failure occurs while writing bus-type motor parameters. Use the Inovance background tool to write the bus-type motor parameters again.
- Confirm whether software has been updated. Set an incorrect drive model (2001-0Bh), power on again, then set the correct drive model and power on again.
- If the fault is still reported after repeatedly powering on and repeating operations 1 and 2, the servo drive is faulty. Replace the servo drive.