Description
The teaching position setting was incorrect and weaving could not be executed.
Subcode description
Among the weaving start point,
end point, and reference point,
two or three points are on the
same point.
Causes and remedies
| Cause | Remedy |
|---|---|
| Software (incorrect setting) | Check the position settings so that the weaving start point, end point, and reference point are not set to the same point. |
| Other | If the alarm occurs again after implementing the countermeasures, contact our service department and describe the circumstances when CMOS.BIN was saved (operating procedure, etc.). |