Description
The relay number which was detected in the ladder program was out of range.
Subcode description
There is invalid relay number in
the USER LADDER.
Causes and remedies
| Cause | Remedy |
|---|---|
| Software (incorrect setting) | Compile the ladder program in management mode and change the relay number at the error location to a value within the valid range. Valid ranges: General-purpose inputs: 00010 through 05127; General-purpose outputs: 10010 through 15127; External inputs: 20010 through 25127; External outputs: 30010 through 35127; Specific inputs: 40010 through 41607; Specific outputs: 50010 through 53007; I/F panel inputs: 60010 through 60647; Auxiliary relays: 70010 through 79997; Control inputs: 80010 through 85127; Virtual inputs: 87010 through 87207; Network inputs: 27010 through 29567; Network outputs: 37010 through 39567 |
| Other | If the alarm occurs again after implementing the countermeasures, contact our service department and describe the circumstances when CMOS.BIN was saved (operating procedure, etc.). |