Description
The type code of the capacitor unit arg in drive module arg is different from the type code specified in the configuration file. The installed capacitor unit type is arg and the configuration type is arg.
Consequences
It will not work unless this fault is corrected. The system enters the "system interruption" state.
Possible causes
The configuration file contains incorrect values, the configuration key is incorrect, or the hardware is of the wrong type. If the capacitor unit has been replaced recently, it is possible that a capacitor unit with the wrong type code was installed or the key was not replaced with one that corresponds to the correct hardware/software combination
Recommended actions
- Make sure the values in the configuration file match the installed hardware.
- Make sure the configuration key matches the installed hardware/software combination. Its configuration data is described in Technical Reference Manual - system parameter.
- If you have recently replaced a capacitor unit, make sure you use a unit with the correct type code.