Error handling: Motor power OFF.
Error reset: Possible.
Content: When RUN/HOLD is switched from “RUN” to “HOLD”, the setting for a 2-second delay before motor power is cut off does not match between the software and hardware.
Main causes:
-
A 2-second delay is set in the software, but no delay is set in the hardware.
-
No delay is set in the software, but a 2-second delay is set in the hardware.
-
A problem with the power sequence board.
Countermeasures:
-
To set a 2-second delay, set SW2-2 on the power sequence board to ON, and set [Effective backup time] to "Standard" under [2 Hardware settings] in auxiliary function 2021 [System settings 1].
-
To set no time delay, turn SW2-2 on the power sequence board OFF, and set [Effective backup time] to "None" under [2 Hardware settings] in auxiliary function 2021 [System settings 1].
-
Replace the power sequence board.