1677
Category: Alarm
Cause
- The same DI function is assigned repeatedly to different physical DI terminals;
- A DI function is assigned to both a physical DI terminal and communication control
Corrective action
- The same function is configured for multiple physical DI terminals in P04.01~P04.09;
- A function assigned in P04.01~P04.09 is enabled together with its corresponding binary bit in P09.05~P09.08; see the instructions for P09.05~P09.08 and reassign the DI functions