Cause:
The arc ending time exceeds the set time.
Troubleshooting:
After ARCOFF is executed, arc termination does not complete normally within the arc termination time set in the arc termination parameters.
Solution:
Check whether communication between the welding machine and the robot is normal.
Case sharing:
None.