[Cause]
The teaching position is located in the singular point area, which is a warning indicating that the teaching position is modified to control the rotation of the J4 axis.
[Countermeasure]
If you do not want to automatically modify the teaching position, set it to $RA_PARAMGRP[g].$USE_START_J4 = FALSE.