Error handling: Motor power OFF.
Error reset: Possible.
Description: The power supply unit control board (1VH) detects this error when a mismatch persists for 10 seconds or longer in any of the controller's safety circuits.
Main causes:
-
The 2 safety circuit systems do not match.
-
The power supply unit control board is faulty.
Countermeasures:
-
If another safety circuit mismatch error (such as D1518, emergency stop state mismatch in the safety circuits) occurs first, troubleshoot according to that error.
-
Replace the power supply unit control board.
Reference: Select <Display 1> → → <Safety Circuit Monitor 2> on the teach pendant screen to check the safety circuit status. For details of safety circuit input monitoring, refer to the Operation Manual.

[NOTE]
- This error does not occur if the safety circuit is configured as a single circuit.
- This error can be reset only when the single and double circuits are both open (OFF) at the same time. If either circuit is closed, the error cannot be reset.