Description
An error occurred during the SDCA01 board control check.
Subcode description
The safety board does not support individual external-axis control using a 2-side contactor.
Causes and remedies
| Cause | Remedy |
|---|---|
| ASF01 board (abnormal) | 1. Turn the power off and back on. 2. If the alarm recurs, replace the ASF01 board with a product that supports individual external-axis control using the 2-side contactor. |