Description
An error occurred in conveyor synchronization execution.
Subcode description
The base axis specified in the conveyor characteristic file is not 0, 1, or 2.
Causes and remedies
| Cause | Remedy |
|---|---|
| Software (incorrect setting) | Set the base axis specification in the conveyor characteristic file to one of 0, 1, or 2. |