Error handling: Controller power OFF;
Error reset: Possible
Description: The DC24V power supplied from the control power AVR to the power sequence board is outside the rated range.
Main causes:
-
Controller power was switched off using external remote OFF.
-
The control power supply AVR is faulty.
-
A problem with the power sequence board.
-
The 24V power supply wiring inside the controller has a ground fault or short circuit.
Countermeasures:
-
Check whether controller power was switched off using external remote OFF. *
-
Replace the AVR.
-
Replace the power sequence board.
-
Check the 24V wiring inside the controller for a ground fault or short circuit.
- This error may occur when the external control power OFF function is used to turn the control power OFF, but this does not indicate an abnormality.