Description
The YRC1000 verifies if the parameter specification is the same as the OT signal information. This alarm occurs if the YRC1000 detects an error in the verification process.
Subcode description
Subcode: the control-group parameter specification does not match the OT-signal information.
Causes and remedies
| Cause | Remedy |
|---|---|
| Software (incorrect setting) | Check the connection (OT) settings in maintenance mode. |