Description
The periodically executed self-diagnostic function for the general-purpose safety output signals of the ASF02 board and ASU03 unit detected an error.
Subcode description
The meaning of each sub code is
as follows:
D01:XOUT01
D02:XOUT02
D03:XOUT03
D04:XOUT04
D05:XOUT05
D06:XOUT06
D07:XOUT07
D08:XOUT08
D09:XOUT09
D10:XOUT10
D11:XOUT11
D12:XOUT12
D13:XOUT13
D14:XOUT14
D15:XOUT15
D16:XOUT16
Causes and remedies
| Cause | Remedy |
|---|---|
| Cable (abnormal) | 1. Reset the alarm. 2. If the alarm recurs, check the connections between the ASF02 board, ASU03 unit, and ASF02 board, checking for loose connectors and cable continuity. |
| ASF01 board (abnormal) | 1. Reset the alarm. 2. If the alarm recurs, replace the ASF01 board. For a system with multiple ASF01 boards connected, replace the ASF01 board connected to the signal that generated the alarm. |
| ASF02 board (abnormal) | 1. Reset the alarm. 2. If the alarm recurs, replace the ASF02 board. For a system with multiple ASF02 boards connected, replace the ASF02 board connected to the signal that generated the alarm. |
| ASU03 unit (abnormal) | 1. Reset the alarm. 2. If the alarm recurs, replace the ASU03 unit. For a system with multiple ASU03 units connected, replace the ASU03 unit connected to the signal that generated the alarm. |
| Other | If the alarm occurs again after implementing the countermeasures, contact our service department and describe the circumstances when CMOS.BIN was saved (operating procedure, etc.). |