[Cause]
Window shift tool error. The window shift tool must be taught again because the software was updated.
[Countermeasure]
Do the following. In addition, for ease of description, it is assumed that the visual program performed by the window transfer tool is VP1 and the visual program to calculate the window transfer tool reference result is VP2.
1. In [Offset coordinate system] of VP2, select the same coordinate system as [Offset coordinate system] of VP1. Reset the reference data at this time.
2. Reset VP2 baseline data.
3. Use the TP program to perform VP2 vision detection and offset acquisition, and store the results in a vision register.
4. Open the VP1 teaching interface, and teach the search regions and measurement regions of all VP1 sub-tools again.