Description
The type code of the rectifier unit arg in drive module arg is different from the type code specified in the configuration file. The installed rectifier unit type is arg and the configured type is arg.
Consequences
It will not work unless this fault is corrected. The system will enter SYS FAIL state.
Possible causes
The configuration file might contain incorrect values; the configuration key might be incorrect; or the hardware might be the wrong type. If the rectifier unit has been replaced recently, it is possible that a rectifier unit with the wrong type code was installed or the key was not replaced with one that corresponds to the correct hardware/software combination
Recommended actions
- Make sure the values in the configuration file match the installed hardware.
- Make sure the configuration key matches the installed hardware/software combination. Its configuration data is described in Technical Reference Manual - system parameter.
- If the rectifier unit has been recently replaced, ensure that a unit with the correct type code is used.