Error handling: Motor power OFF.
Error reset: Possible.
Description: An external power supply abnormality was detected on the power regeneration control board.
Main causes:
-
A problem with the power regeneration control board.
-
A short circuit, short circuit, or faulty wiring in the harness between the circuit breaker and power regeneration unit.
-
A problem with the power supply system (phase loss, three-phase imbalance, reduced supply voltage, or frequency outside 50Hz±5% or 60Hz±5%).
-
A problem with the power supply unit.
Countermeasures:
-
Replace the power regeneration unit.
-
Check the wiring between the circuit breaker and the power regeneration unit.
-
Check the power supply system for abnormalities.
-
Replace the power supply unit.